Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure) and the
adjustment conditions are compatible. The adjustment conditions for this appliance are stated on the data
badge which is fitted on the back panel.
This appl
iance is not designed to be connected to a combustion products evacuation device. It must be
installed and connected in accordance with current installation regulations. particular attention should be given
to the relevant requirements regarding ventilation.
MODEL NUMBERS C60DPF, C60DTF
Category II2H3+ (GB)
These models are set to burn NATURAL GAS (G20) at 20 mbar but can be converted for use on BUTANE (G30)
at 28-30mbar or PROPANE (G31) at 37mbar with the use of the LPG conversion kit that can be obtained
free of
charge, if you contact our Genuine Parts and Accessories department (see Key Contacts, back page).
GAS SAFETY (INSTALLATION & USE) REGULATIONS
It is the law that all gas appliances are installed by competent persons in accordance with the current edition of
the above regulations. It is in your interest and that of safety to ensure compliance with the law. In the UK,
CORGI registered
installers work to safe standards of practice. The cooker must also be installed in accordance
with BS 6172. Failure to install the cooker correctly could invalidate the warranty liability claims and could lead
to prosecution.
LOCATION
The cooker may be located in a kitchen, kitchen/diner or a bed-sitting room, but not in a room containing a bath
or shower. The cooker must not be installed in a bed-sitting room of less than 20m
3
.
When adjusted for use on Butane (G30) or Propane (G31), the cooker must not be installed in a room or internal
space below ground level, e.g. in a basement.
PROVISION FOR VENTILATION
The room containing the cooker should have an air supply in accordance with BS 5440: Part 2.
The room must have an opening window or equivalent; some rooms may also require a permanent vent. If the
room has a vo
lume between 5 and 10m
3
, it will require an air vent of 50cm
2
effective area unless it has a door
which opens directly to outside. If the room has a volume of less than 5m
3
, it will require an air vent of 100cm
2
effective area. If there are other fuel burning appliances in the same room, BS 5440: Part 2 should be consulted
to determine air vent requirements.