Canterbury Freestanding Instruction ManualPlease read this manual before installing and using this heater.Please leave instruction manual with the ow
10 | Cannon Canterbury Freestanding FRONT GLASS REMOVAL AND INSTALLATIONFront Glass Installation1. Place heater in position. (Check ue and gas conn
Cannon Canterbury Freestanding | 11FLUEING INSTALLATIONThis heater is a ued appliance. It must be properly connected to a ue system in accordance wi
12 | Cannon Canterbury Freestanding Electrical ConnectionThis appliance is designed to operate on 240V AC power supply. Failure to operate unit at cor
Cannon Canterbury Freestanding | 13LOG INSTALLATION1. The burner is contained within the burner chamber. Refer FIG 12.2. Carefully unpack the log se
14 | Cannon Canterbury Freestanding SETTING THE GAS PRESSURE1. Gas valve layout is as indicated in FIG 17. Pressures for ‘Burner high ame’ and ‘Bur
Cannon Canterbury Freestanding | 15To Replace The Ignition Module (Device)1. Unplug wire connectors from ignition module.2. Remove module mounting
16 | Cannon Canterbury Freestanding SERVICE INSTRUCTIONS (DO NOT MODIFY THIS APPLIANCE)Clear Silicon TubeBlack Silicon TubeFIG 23 Room FanFlame Sense
Cannon Canterbury Freestanding | 17WIRING DIAGRAMFIG 26FIG 27 Switch Control Diagram highlighting NG/LP settings & audible beep.NATURALLY ASPIRATE
18 | Cannon Canterbury Freestanding TROUBLESHOOTINGTo check the operation of the heaters electrical system you will require a digital multimeter with
Cannon Canterbury Freestanding | 19TROUBLESHOOTINGOther Possible FaultsNo gas to burner. • The gas valve should open at the same time as the igniter
2 | Cannon Canterbury Freestanding CONTENTS PAGEWARRANTY 3SAFETY WARNINGS 5OPERATION 6OPTIONAL ACCESSORIES 7CANTERBURY FREESTANDING SPECIFICATIONS 8CA
20 | Cannon Canterbury Freestanding Gmk 10025 Gmk 10030AS4553:2008Part Number:F3842_BFor service to this appliance or spare parts contact the CANNON
Cannon Canterbury Freestanding | 3WARRANTYThis Warranty against defects for your newly purchased Cannon product is proudly prepared by Sampford IXL Pt
4 | Cannon Canterbury Freestanding Don’t risk your appliance warrantyOnly a licensed person will give you a Compliance Certicate, showing that the w
Cannon Canterbury Freestanding | 59. If removed, the glass window must be put back onto the unit prior to operating the heater.10. Installation and
6 | Cannon Canterbury Freestanding Operating InstructionsPlug the power cord into the switch socket and turn on the power to the heater (FIG 1). Alter
Cannon Canterbury Freestanding | 7OPTIONAL ACCESSORIESProduct codes• Remote thermostat: RTKIT• Canterbury mesh guard: CANTFSMG-B• Flue Kit: FLUERO
8 | Cannon Canterbury Freestanding Gas type Natural or Propane gas, as indicated on data plateGas consumption 26 MJ/hr inputEnergy output 5.98 kW / 2
Cannon Canterbury Freestanding | 9CANTERBURY FREESTANDING INSTALLATION INSTRUCTIONSOverview1. This appliance MUST be installed by a suitably license
Comments to this Manuals